Hot Water is an everyday need for modern living. Traditionally, water is heated by burning fossil fuels or using electric heaters.
These traditional methods of water heating consume much higher energy (electrical or fossil fuels), resulting in energy wastage.
Increasing energy costs of gas or oil heating systems, coupled with the need to meet Co2 emission targets has resulted in the growing interest in dedicated heat pumps. Rather than burning fossil fuels to produce heat and consequently Co2 emission, dedicated heat pumps use renewable energy from the environment like air, ground, and water. It consumes up to 70% less primary energy and therefore drastically reduces the pollution resulting from the use of fossil fuels.
Goldstar Heat Pump (UHP) Series is a more efficient solution for heating water. It utilizes naturally available heat from water, ground, and even winter air and applies a vapor compression refrigerant cycle, consuming nearly one-quarter of the electrical energy required for traditional water heating. At 75% reduced energy consumption, this contributes to cleaner air.
Goldstar has developed a full range (from 200 Litres/hr To 1500 Litres/hr) of UHP water heating units built on heating optimized Special Compressors to provide seasonal efficient heating capacity and effective domestic hot water production in residential and commercial building applications. These are available for use with multiple refrigerants like R417A, R407C, R22, and R134A.
It is designed to deliver 55ºC – 60ºC water temperature irrespective of the weather conditions. It can operate from a wide ambient from 10ºC to 43ºC. UHP units come fitted with Best–In–Class “Shell & Tube” heat exchanger technology. These are easier to service compared to other available condensers in the field.
UHP series is designed for simple & easy operation in the field for end – users like Hotels, Hostels, Factories & Restaurants, etc. These units come with a “Simple User Interface” which allows service teams to get advance warnings about field failures and simple error codes for easy diagnosis & troubleshooting. This reduces downtime and increases system life.
Uratom Special compressor provides energy efficient alternative for hot water, swimming pool Heating & space heating to replace the use of electric heaters and fuel-fired boilers. It is designed based on Uratomʼs strong manufacturing experiences, that recognizes as a reliable and effective product. On this strong base, Uratom provides heating special technology and multiple new product design features.
| All In One | Monoblock | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Model | Unit | UT01.5D/AIO | UT02D/AIO | UT02.6D/AIO | UT01D | UT01.2D | UT02D | UT03D | UT05D | |
| Water Heating | kW | 3.6 | 3.6 | 5.3 | 8.0 | 11.4 | 19.3 | |||
| Heating Capacity | BTU/h | 12288 | 12288 | 18090 | 27306 | 38912 | 65877 | |||
| Heating Input Power | kW | 0.9 | 0.9 | 1.3 | 2.0 | 2.7 | 4.5 | |||
| Heating Input Current | A | 4.1 | 4.1 | 5.9 | 9.0 | 12.3 | 9.0 | |||
| Refrigerant | R417A/R22/R410A/R134A/R407C | R22/R417/R410A/R134A/R470C | ||||||||
| Power Supply | 220V/1ø/50Hz | 220V/1ø/50Hz | 380V/3ø/50Hz | |||||||
| Controller Type | Intelligent & LCD | Intelligent & LCD | ||||||||
| Compressor | Compressor Type | Rotary*1 | Rotary*1 | Scroll*1 | ||||||
| Compressor Brand | Copeland / Panasonic / Hitachi | Copeland / Panasonic / Hitachi | ||||||||
| Fan Motor | Fan Type | Low noise high-efficiency axial type | Low noise high-efficiency axial type | |||||||
| Fan Input Power | W | 12 | 28 | 90 | ||||||
| Fan Speed | RPM | 850 | 850 | |||||||
| Heat Exchanger | External Copper Coil | Shell & Tube | ||||||||
| Protection | Low-Pressure Protection | Yes | Yes | |||||||
| High-Pressure Protection | Yes | Yes | ||||||||
| Automatic Defrosting System | Yes | Yes | ||||||||
| Overload Protection | Yes | Yes | ||||||||
| Dimension | Unit Size | mm | ø510*1660 | ø570*1750 | ø570*2100 | 1000*365*560 | 1115*480*720 | 1111*475*1255 | ||
| Approx. Weight | kg | 75 | 85 | 95 | 45 | 52 | 60 | 105 | 155 | |
| Noise in 1 meter | dB(A) | ≤43 | ≤54 | ≤55 | ≤58 | |||||
| Water Tank | Water Tank Volume | ltr | 150 | 200 | 260 | |||||
| Water Pipe Size | mm | ø20 | ø25 | |||||||
| Rated Heated Water Output | 100 | 150 | 200 | 300 | 500 | |||||
| Cabinet | Galvanized Powder Coated Steel | Galvanized Powder Coated Steel | ||||||||
| Heating: Ambient temp. (DB/WB); 20oC / 15oC, Water temp (input/output) : 15oC / 55oC. | ||||||||||
| Model | UT040Sw | UT060Sw | UT100Sw | UT130Sw | UT150Sw | ||
| Water Heating | Heating Capacity | kW | 13.5 | 22.8 | 33.5 | 45.7 | 54.0 |
| BTU/h | 46080 | 77824 | 114346 | 155989 | 184319 | ||
| Cooling Capacity | kW | 8.2 | 13.5 | 20 | 30 | 37 | |
| BTU/h | 27989 | 46080 | 68200 | 102400 | 12628 | ||
| Heating Input Power | kW | 2.4 | 4 | 6 | 8.2 | 9.6 | |
| Cooling Input Power | kW | 2.7 | 4.3 | 6.5 | 9.6 | 12 | |
| Heating Input Current | A | 11 | 7.2 | 10.8 | 14.7 | 17.2 | |
| Cooling Input Current | A | 12.3 | 7.7 | 11.6 | 17.2 | 21.5 | |
| COP | 5.62 | 5.7 | 5.58 | 5.57 | 5.62 | ||
| Refrigerant | R417A (R22/R407C/R410A for option) | ||||||
| Power Supply | 220V/1ø/50Hz | 380V/3ø/50Hz | |||||
| Controller Type | Intelligent & LCD | ||||||
| Compressor | Compressor Type | Scroll*1 | Scroll*1 | Scroll*1 | Scroll*2 | Scroll*2 | |
| Compressor Brand | Copeland / Panasonic / Hitachi | ||||||
| Fan Motor | Fan Type | Low noise high-efficiency axial type | |||||
| Fan Input Power | W | 90 | 250 | 250 | 250 | 250 | |
| Fan Speed | rpm | 750 | 850 | 850 | 850 | 850 | |
| Heat Exchanger | Shell & Tube | ||||||
| Protection | Low-Pressure Protection | Yes | |||||
| High-Pressure Protection | Yes | ||||||
| Automatic Defrosting System | Yes | ||||||
| Overload Protection | Yes | ||||||
| Dimension | Unit Size | mm | 1110*470*680 | 855*775*1095 | 980*860*1525 | 1550*845*1180 | 1550*845*1180 |
| Approx. Weight | kg | 68 | 125 | 220 | 270 | 350 | |
| Noise in 1 meter | dB(A) | ≤54 | ≤56 | ≤58 | ≤60 | ≤63 | |
| Water piping | Water Pipe Size | mm | ø50 | ø50 | ø50 | ø63 | ø63 |
| Water Flow Volume | ltr/h | 4000 | 6000 | 10,000 | 13,000 | 15,000 | |
| Cabinet | Galvanized Powder Coated Steel | ||||||
| Heating Working Condition: Outdoor DB/WB temp: 24oC/19oC, 62.5%RH, Inlet Water temp: 26oC. Cooling Working Condition: Outdoor DB/WB temp: 35oC/24oC, 68%RH, Inlet Water temp: 30oC. |
|||||||
|---|---|---|---|---|---|---|---|